Key Features
- Pure Sine Wave Output delivers clean, stable power for sensitive appliances and equipment
- High Efficiency with a peak efficiency of 94%, ensuring maximum energy conversion from solar panels and battery storage
- Flexible Charging Options support both utility grid and solar MPPT charging, with a 3-step charging algorithm for optimized battery life
- Surge Capacity handles 2x the rated power for 5 seconds, ideal for high-inrush load applications
- Overload Protection with built-in protection against overload (5s at ≥150% and 10s at 100%-150% load) ensuring system reliability
- MPPT Solar Charging supports a maximum PV array power of 2000W with an MPPT voltage range of 30-400 VDC, ensuring efficient solar energy harvesting
- AC Charging Current up to 60 A for fast utility charging, with adjustable settings for various battery types (Flooded, AGM, Gel)
- Versatile Voltage Input supports a wide input voltage range from 170V to 280V AC, with automatic frequency detection (50Hz/60Hz)
- Short Circuit Protection with a circuit breaker for added safety in case of electrical faults
- Compact & Lightweight design (4.4 kg) and compact dimensions (36 mm x 270 mm x 100 mm) for easy installation
- Wide Operating Temperature Range from -10°C to 50°C, making it suitable for diverse climates
- CE Certified meets international safety standards, ensuring reliability and quality
- Fast Transfer Time of 10 ms for UPS and 20 ms for appliances, minimizing power disruption during switching
Product Specifications
Type
|
Hybrid Inverter
|
Rated Output Power
|
2000 Va / 1600 W
|
Output Voltage Waveform
|
Pure Sine Wave
|
Output Voltage Regulation
|
230 Vac ±5%
|
Output Frequency
|
50 Hz
|
Peak Efficiency
|
94%
|
Overload Protection
|
5s At ≥150% Load, 10s At 100%-150% Load
|
Surge Capacity
|
2x Rated Power For 5s
|
Nominal Dc Input Voltage
|
12 Vdc
|
Cold Start Voltage
|
11.5 Vdc
|
High Dc Recovery Voltage
|
14 Vdc
|
High Dc Cut-Off Voltage
|
16 Vdc
|
No Load Power Consumption
|
25 W
|
Charging Algorithm
|
3-Step
|
Ac Charging Current (Maximum)
|
60 A (At 230 Vac Input)
|
Bulk Charging Voltage Flooded Battery
|
14.6 Vdc
|
Bulk Charging Voltage Agm/Gel Battery
|
14.1 Vdc
|
Floating Charging Voltage
|
13.5 Vdc
|
Maximum Pv Array Power
|
2000 W
|
Nominal Pv Voltage
|
240 Vdc
|
Pv Array Mppt Voltage Range
|
30 Vdc – 400 Vdc
|
Max Pv Array Open Circuit Voltage
|
400 Vdc
|
Maximum Charging Current
|
80 A
|
Input Voltage Waveform
|
Sinusoidal (Utility Or Generator)
|
Nominal Input Voltage
|
230 Vac
|
Low Loss Voltage
|
170 Vac ±7v (Ups), 90 Vac ±7v (Appliances) Low Loss Return Voltage
|
High Loss Voltage
|
280 Vac ±7v
|
High Loss Return Voltage
|
270 Vac ±7v
|
Maximum Ac Input Voltage
|
280 Vac
|
Nominal Input Frequency
|
50 Hz / 60 Hz (Auto Detection)
|
Low Loss Frequency
|
46 ±1 Hz
|
Low Loss Return Frequency
|
47 ±1 Hz
|
High Loss Frequency
|
54 ±1 Hz
|
High Loss Return Frequency
|
53 ±1 Hz
|
Output Short Circuit Protection
|
Circuit Breaker
|
Efficiency (Line Mode)
|
>95% (Rated Load, Battery Fully Charged)
|
Transfer Time
|
10 Ms For Ups, 20 Ms For Appliances General
|
Safety Certification
|
Ce
|
Operating Temperature Range
|
-10°C To 50°C
|
Storage Temperature
|
-15°C To 60°C
|
Humidity
|
5% To 95% Relative Humidity (Non-Condensing)
|
Dimensions (D X W X H)
|
36 Mm X 270 Mm X 100 Mm
|
Net Weight
|
4.4 Kg
|